Description
APPLICATION:
- Systems with typical cold start-up and high operating temperatures.
- Systems requiring a high degree of load-carrying capability and anti-wear protection.
- Industrial and mobile equipment hydraulic systems operating at high pressures and temperatures in critical applications.
FEATURES AND BENEFITS:
- Resistance to viscometric changes.
- Shear stable, high viscosity index products that maintain protection of components over a wide temperature range.
- Low foaming tendency, even at high circulation rates.
- Good water separation allows removal of water to reduce damages caused by corrosion.
- Excellent thermal stability.
- Outstanding anti-wear properties reduce the abrasion and provides the smooth operation of a hydraulic system over a long period of time.
Compatible with all gaskets, O-rings and sealing materials used in hydraulic and circulating lubrication systems.
PERFORMANCE LEVEL:
Meet the performance requirements of:
- AIST 126
- ASTM D6158 (HV)
- DIN 51524 Part 3 (HVLP)
- ISO 11158 (HV)
TYPICAL PROPERTIES:
ISO VG Grade | Test Method | 15 | 32 | 46 | 68 | 100 | 150 |
Density @ 15°C, kg/l | ASTM D4052 | 0.880 | 0.866 | 0.870 | 0.876 | 0.879 | 0.880 |
Viscosity, cSt @ 40°C | ASTM D445 | 15.1 | 31.2 | 45.7 | 66.1 | 98.0 | 142.2 |
Viscosity, cSt @ 100°C | ASTM D445 | 3.81 | 6.3 | 8.12 | 10.9 | 14.2 | 17.9 |
Viscosity Index | ASTM D2270 | 150 | 158 | 152 | 156 | 149 | 140 |
Flash Point COC, °C | ASTM D92 | 160 | 218 | 222 | 160 | 218 | 222 |
Pour Point, °C | ASTM D97 | -45 | -39 | -36 | -45 | -39 | -36 |
Demulsibility, min. | ASTM D1401 | 10 | 10 | 10 | 15 | 10 | 10 |
Rust Prevention | ASTM D665A | Pass | Pass | Pass | Pass | Pass | Pass |
Copper Corrosion | ASTM D130 | 1a | 1a | 1a | 1a | 1a | 1a |
* The information provided is to our best knowledge, true & accurate. Subjected to change without notification due to continual product research and development.